mikroman wrote: ↑Mon Nov 09, 2020 2:12 pm
... but in 20 years of experience I have had only one such case (combination of atmospheric discharge and poor grounding).
All I can go by is by the comments my friend has given me regarding the ETG1000
I like Elenos equipment, my only observation is the power supplies tend to be a bit temperamental.
I have a few of the ETG 1000's and have had PSU failures with most of them but typically after power outages.
+
One of the stations I engineer for in Ireland also used to have ETG1000's and had the same issue.
His experiences was from locations in Ireland and the island of Tenerife
He told me he never tried to repair them. they installed some ebay China PSU's
Also I am in Gran Canaria.
We get a lot of mains glitches and spikes even before we talk about atmospheric discharges
So I was asking if anyone had similar issues with the said power supplies and if they could be easily repaired ?
Here is a picture of an original Dead PS
ELENOS ETG1000 PSU-5-s.jpg
You do not have the required permissions to view the files attached to this post.